Abstract
The dependence of the form of the EMG-force relation on key motoneuron and muscle properties was explored using a simulation approach. Surface EMG signals and isometric forces were simulated using existing motoneuron pool, muscle force, and surface EMG models, based primarily on reported properties of the first dorsal interosseous (FDI) muscle in humans. Our simulation results indicate that the relation between electrical and mechanical properties of the individual motor unit level plays the dominant role in determining the overall EMG amplitude-force relation of the muscle, while the underlying motor unit firing rate strategy appears to be a less important factor. However, different motor unit firing rate strategies result in substantially different relations between counts of the numbers of motoneuron discharges and the isometric force. Our simulation results also show that EMG amplitude (estimated as the average rectified value) increases as a result of synchronous discharges of different motor units within the pool, but the magnitude of this increase is determined primarily by the action potential duration of the synchronized motor units. Furthermore, when the EMG effects are normalized to their maximum levels, motor unit synchrony does not exert significant effects on the form of the EMG-force relation, provided that the synchrony level is held similar at different excitation levels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.