Abstract

In stable continuous flow system (CFS), excess sludge with ultrasonic treatment was returned. The effect of ultrasonic density, ultrasonic time, ultrasonic pulse and recycled ratio of ultrasonic sludge on excess sludge reduction was studied, and effluent water quality and sludge settling ability were determined. Results showed that under ultrasonic density 0.4 W/mL, ultrasonic time 5 min, recycled ratio of ultrasonic sludge 1:24, excess sludge reduction ratio was above 90%, effluent water quality could achieve II-class criteria specified in the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002), SVI was about 100 mL/gMLSS, sludge settled properly. Ultrasonic pulse had hardly any effect on excess sludge reduction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.