Abstract
The paper demonstrated cost-effective one-step hydrothermal process to synthesize TiO2 microrods modified with Cr2O3 nanoparticles. The crystal structure, microstructure and chemical composition of the obtained materials were characterized by XRD, SEM, TEM and EDS analysis. Subsequently, for gas sensor tests the sensors were fabricated onto a ceramic tube having a designed pair of Au electrodes with four Pt wires. The results indicate that the sensors based on the optimal content of Cr2O3 nanoparticles modified TiO2 microrods possess excellent gas-sensing performance to acetone. Specifically, the sensor based on optimal 3% Cr2O3 modified TiO2 microrods exhibited high response (15), fast response/recovery time (5/28 s), outstanding selectivity (against 100 ppm ethanol, methanol and formaldehyde) and good stability (1–40 days) towards 100 ppm acetone at 300 °C. Relying on the analysis, we infer that performance can be controlled by varying the Cr2O3 contents. A plausible sensing mechanism is also discussed to explain the reasons for the enhanced acetone sensing with Cr2O3–TiO2 heterostructures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Materials Science: Materials in Electronics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.