Abstract
This paper describes development and actual utilization of a fab-wide equipment monitoring system using a secondary port separating a primary port shared by an MES and a fab-wide FDC (fault detection and classification) system. In data collection of equipment parameter, a new concept of important parameter is introduced. As an example of the fab-wide FDC, an FDC of a slurry flow rate fault in CMP equipment from the start-up is demonstrated. Moreover, in order to quantitatively estimate equipment quality, Cpk for each parameter of equipment in fab-wide is calculated and it is confirmed that equipment quality is increasing from starting up equipment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.