Abstract

A new ion-selective polyvinyl chloride membrane electrode based on Schiff base [N,N′-bis(1-hydroxynaphthalene-2-carbaldehyde)-o-phenylenediamine] as an ionophore is successfully worked out as sensor for Zn(II) ions. The electrode shows excellent potentiometric response characteristics and displays a linear emf versus log[Zn2+] response over a wide concentration range of 1.0 × 10–7‒0.1 M with nernstian slope of 29.0 ± 0.1 mV/decade with the detection limit of 1.8 × 10–8 M. The sensor exhibits the advantages of fast response time (<10 s). The lifetime of the sensor is about 3 months. It was used as an indicator electrode in the potentiometric titration of Zn(II) with EDTA and for the determination of Zn(II) in pharma samples. The results were validated by using quantum mechanical density functional theoretical calculations. Theoretical studies proved prominent affinity of ligand towards Zn(II) ion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.