Abstract

Having similar properties with natural bone, has made porous NiTi shape memory alloy (SMA) a promising material for biomedical applications. In this study porous NiTi SMA has synthesized with 30 and 40 vol.% green porosity by self propagating high temperature synthesis (SHS) from elemental Ni and Ti powders. After synthesizing, the average porosity of specimens reached to 36.8 and 49.8% for green compacts with 30 and 40 vol.% of green porosity, respectively. Combustion products were characterized by XRD, SEM, EDS and electrochemical polarization test. Although desired B2 (NiTi) phase was the dominant phase, other phases like Ti2Ni, Ni3Ti and Ni4Ti3 are found. Electrochemical polarization analysis in simulated body fluids (SBF) shows that, synthesized porous NiTi has better corrosion resistance than solid one and hydroxy apatite coating on porous NiTi worsen electrochemical corrosion resistance which is because of bioactive behavior of hydroxy apatite.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.