Abstract

Titanium and its alloys are suitable for biomedical applications owing to their good mechanical properties and biocompatibility. Beta-type Ti–Mn alloys (8–17 mass% Mn) were fabricated by metal injection molding (MIM) as a potential low cost material for use in biomedical applications. The microstructures and mechanical properties of the alloys were evaluated. For up to 13 mass% Mn, the tensile strength (1162–938MPa) and hardness (308–294HV) of the MIM fabricated alloys are comparable to those of Ti–Mn alloys fabricated by cold crucible levitation melting. Ti–9Mn exhibits the best balance of ultimate tensile strength (1046MPa) and elongation (4.7%) among the tested alloys, and has a Young’s modulus of 89GPa. The observed low elongation of the alloys is attributed to the combined effects of high oxygen content, with the presence of interconnected pores and titanium carbides, the formation of which is due to carbon pickup during the debinding process. The elongation and tensile strength of the alloys decrease with increasing Mn content. The Ti–Mn alloys show good compressive properties, with Ti–17Mn showing a compressive 0.2% proof stress of 1034MPa, and a compressive strain of 50%.