Abstract

We fabricated gas sensors based on field ionization from multiwalled carbon nanotube (MWCNT) arrays grown on porous silicon templates. MWCNTs were grown through thermal chemical vapor deposition. We measured breakdown voltages, discharge and pre-discharge currents of the device for various gases in different concentrations. Our gas ionization sensors (GIS) presented good sensitivity, selectivity and short response time. The GISs based on porous substrates showed higher discharge current and good mechanical stability in comparison to those which were fabricated on polished silicon substrates. Additionally, we applied a high electric field to align CNTs. This increased the pre-breakdown current. Also, introducing humidity in dry air caused enhancement in pre-breakdown current and lowered breakdown voltage. We also used our GIS in monitoring gas mixtures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.