Abstract
Tris(2,2'-bipyridyl)ruthenium (II) (Ru(bpy)2+) electrogerated chemiluminescence (ECL) sensor was fabricated by immobilization of Ru(bpy)2+ complex on conducting polymer@SiO2/Nafion composite film on surface of glassy carbon electrode. The conducting polymer@SiO2 nanocomposites were prepared by coating polyaniline (PANI), polypyrrole (PPy), and polythiophene (PTh) on the surface of the SiO2 sphere. The conducting polymer@SiO2 nanocomposite was characterized by scanning electron microscopy (SEM), Transmission electron microscopy (TEM), and atomic force microscopy (AFM). The sensitivity and reproducibility of the prepared ECL sensor to tripropylamine (TPA) was evaluated. As a result, the PPy@SiO2 composite electrode exhibited high sensitivity and good reproducibility compared to that obtained with PANI@SiO2 and PTh@SiO2 composite electrodes because of the strong interaction between PPy@SiO2 and Ru(bpy)2+ complex.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.