Abstract

This article describes the use of computed tomography and rapid prototyping method to produce a wax pattern of a missing ear. Computed tomographic scans were obtained from the patient, and a three-dimensional digital image was produced using a computer-aided design software. Then, the image of the present ear was extracted, and its mirror image was obtained with the software. The pattern of the inverted three-dimensional cast was produced using a rapid prototyping machine. The cast was duplicated in wax of identical dimensions and shape of the opposing ear, and the auricular prosthesis was fabricated with traditional methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.