Abstract
With the development of optical systems used in astronomical and earth observation, aspherical and free-form surfaces are increasingly used because they are lightweight and have improved image quality. As a highly accurate, aberrationless technique, computer-generated hologram (CGH) plays an important role in wavefront testing. At present, the main way to fabricate phase CGH is reactive ion etching, which suffers from low accuracy. To improve the accuracy, physical vapor deposition (PVD) is applied in the fabrication of phase CGH. The wavefront errors of PVD-fabricated phase CGH were analyzed. Testing results indicate that the wavefront error of the CGH is 0.020λ root mean square (RMS), mainly caused by the machine tool orthogonality error rather than the PVD process. The diffraction efficiency of the +1st order is 22.4%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.