Abstract

This paper describes the development of radial grooved micro heat pipes (MHPs) with a three-layer structure. The MHPs were designed to allow separation of the liquid and vapor flow to reduce the viscous shear force. The 5×5 cm 2 MHP array was fabricated by using bulk micromachining and eutectic bonding techniques on 4-in. (1 0 0) silicon wafers. Experiments were undertaken to evaluate the performance of wafers with three different wafer fill rates at different input powers. We glued a heater below the evaporator section, pumped cold water through a square copper heat exchanger above the heat pipe, and pasted 15 K-type thermocouples on both sides of MHP structure to record the variations of surface temperature. After the evaluation, the MHP with 70% fill rate showed the best performance as compared to samples with smaller fill rates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.