A polarization beam splitter (PBS) based on an asymmetrical Mach-Zehnder interferometer (MZI) is experimentally demonstrated on a InP platform. The experimental results show that the polarization extinction ratios (PERs) are 8 dB and 14 dB for transverse-electric (TE) and transverse-magnetic (TM) polarization at 1550 nm, respectively. The PER is greater than 5 dB/12 dB for TE/TM polarization over the full C band wavelength range. Fabrication errors including the waveguide width, arm length, film thickness, and sidewall are analyzed using the beam propagation method. The width and sidewall are the most sensitive factors that affect the performances of this type of PBS. This analysis will improve the fabrication tolerance of the PBS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.