Abstract

The effects of working fluid properties on the gas turbine performance have been investigated. The convective heat transfer rates have been compared for various gases and the gas which is more favorable than air has been determined. It is found that the convective heat transfer coefficient for helium is almost twice that for air. This implies that the helium heat-exchanger needs only half the surface area of tubing for the same temperature difference comparing with one for air, or that higher effectiveness can be obtained economically by using helium.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.