Abstract

Purpose. To determine the specificity of functional and tonographic parameters of the eyeball in children with cataract, aphakia and pseudophakia. Material and methods. A comparative analysis of eye hydrodynamics indices was made according to a simplified procedure, using the Friedenwald nomogram, on 75 children aged 2 to 17 years with cataract (24 eyes), aphakia (21 eyes), pseudophakia (15 eyes), and IOL dislocation (15 eyes), as well as 12 healthy children.Results. In pseudophakia, true IOP was found to fall to 10.00 ± 0.01 mm Hg due to a decrease in aqueous humor production (to 0.10±0.01 mm3 / min) and increase of its outflow (to 0.75 ± 0.02 mm3/min / mm). IOL dislocation led to an increase in true IOP (24.40±1.0 mm Hg) due to an increase in aqueous humor production (4.09±0.05 mm3/min) and a decrease in its outflow (0.010 ± 0.002 mm3/min/mm). In these eyes, clinical manifestations of secondary pseudophakic glaucoma were noted, which are explained by factors obstructing aqueous humor outflow (vitreous prolapse and partial vitreous block) and considered an indication for re-operation.Conclusion. Statistically significant changes of hydrodynamic eye parameters in children with pseudophakia have been detected: increased true IOP in IOL dislocation, and, conversely, reduced true IOP in case of the normal IOL location. The authors believe that eye “hypotension” in case of pseudophakia requires further study.

Highlights

  • To determine the specificity of functional and tonographic parameters of the eyeball in children with cataract, aphakia and pseudophakia

  • A comparative analysis of eye hydrodynamics indices was made according to a simplified procedure, using the Friedenwald nomogram, on 75 children aged 2 to 17 years with cataract (24 eyes), aphakia (21 eyes), pseudophakia (15 eyes), and IOL dislocation (15 eyes), as well as 12 healthy children

  • IOL dislocation led to an increase in true IOP (24.40±1.0 mm Hg) due to an increase in aqueous humor production (4.09±0.05 mm3/min) and Keywords: eye hydrodynamics; cataract; aphakia; pseudophakia; pseudophakic glaucoma; IOL implantation; lens dislocation Conflict of interests: there is no conflict of interests

Read more

Summary

Introduction

To determine the specificity of functional and tonographic parameters of the eyeball in children with cataract, aphakia and pseudophakia. IOL dislocation led to an increase in true IOP (24.40±1.0 mm Hg) due to an increase in aqueous humor production (4.09±0.05 mm3/min) and Keywords: eye hydrodynamics; cataract; aphakia; pseudophakia; pseudophakic glaucoma; IOL implantation; lens dislocation Conflict of interests: there is no conflict of interests. For citation: Khamraeva L.S., Bobokha L.Yu., Katargina L.A. Eye hydrodynamics indicators in children with congenital cataract, aphakia and pseudophakia. ЦЕЛЬ работы — определить особенности клиникофункциональных и тонографических показателей глаз детей с врожденной катарактой, афакией и артифакией.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call