Abstract

During routine pharmaceutical development and scale-up work, severe corrosion of a Hastelloy Alloy C-22 (Alloy 22) filter dryer was observed after single, short (several hour) contact with the product slurry at room temperature. Initial investigations showed that the presence of both 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and HCl was sufficient in an acetonitrile solution to cause rapid corrosion of Alloy 22. More detailed mass loss studies showed initial corrosion rates exceeding 25 mm/y that then decreased over several hours to steady state rates of 3 mm/y to 5 mm/y. The corrosion was highly uniform. Electrochemical measurements demonstrated that although Alloy 22 is spontaneously passive in acetonitrile solution, the presence of HCl leads to the development of a transpassive region. DDQ is a sufficiently strong oxidizer, particularly in acidic solutions, to polarize the Alloy 22 well into the transpassive region, leading to the observed high-corrosion rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.