Abstract

A multi-frame extreme ultraviolet imaging system based on four pinhole cameras, each backed by a gated microchannel plate (MCP) detector, was used to analyze plasma formation and dynamics in wire array z-pinch experiments on the MAGPIE generator (1 MA, 240 ns) at Imperial College (London). The use of pinhole size, object, and image distances, and MCP sensitivity to determine the spatial and spectral response of the diagnostic is discussed. A high magnification, high resolution version of the diagnostic has produced important information on wire initiation and plasma ablation in various materials. A low magnification version has allowed direct study of the snowplough sheath during array implosion, and of plasma instabilities during stagnation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.