Abstract

A multi-frame extreme ultraviolet imaging system based on four pinhole cameras, each backed by a gated microchannel plate (MCP) detector, was used to analyze plasma formation and dynamics in wire array z-pinch experiments on the MAGPIE generator (1 MA, 240 ns) at Imperial College (London). The use of pinhole size, object, and image distances, and MCP sensitivity to determine the spatial and spectral response of the diagnostic is discussed. A high magnification, high resolution version of the diagnostic has produced important information on wire initiation and plasma ablation in various materials. A low magnification version has allowed direct study of the snowplough sheath during array implosion, and of plasma instabilities during stagnation.