Abstract

This paper discusses a method for measuring the frequency-dependent characteristic impedance of transmission lines using time domain reflectometry (TDR) measurements with an open, short and load calibration. Conventional characterization methods using a network analyzer require precise information on the structure of the transmission line to extract the characteristic impedance, which can be cumbersome. In TDR measurements, the effect of the load can be removed using time windowing, which can reduce the error in the measurements. The results of TDR measurements have been compared with those of a network analyzer to quantify the measurement error. Both a low pass filter and a PCB microstrip line have been characterized using this method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.