Abstract

A new technique has been proposed for the extraction of the capacitance of the ultrathin high-K gate dielectrics C/sub di/. The only assumptions made in deriving the mathematical relations for the extraction plots are that, in the accumulation regime, both the space charge and the interface trap capacitances are exponential functions of /spl beta//spl phi//sub s/, where /spl phi//sub s/ is the surface potential. The deviation of the value of the constant |/spl beta/| from that of q/2kT may be considered an indication of the extent of quantization. The proposed technique, and for the sake of comparison, some existing gate dielectric capacitance extraction techniques, were applied to different high-K gate dielectrics. The experimental capacitance-voltage ( C-V) data were taken from the literature, after carefully selecting the high-K gate dielectrics, to obtain varying band offsets and equivalent oxide thickness (EOT). Satisfactory linear fits, to the data points in the extraction plots, were obtained consistently in the case of the proposed technique, and the values of the gate dielectric capacitance C/sub di/, appear to be reasonable, and consistent with the experimental values of /spl beta/. While the classical value of |/spl beta/| is 19.38 V/sup -1/ at 300 K, the experimental value of |/spl beta/| varied from 15.31 V/sup -1/ in the case of an La/sub 2/O/sub 3/ gate dielectric with EOT = 0.47 nm to 5.77 V/sup -1/ in the case of an Al/sub 2/O/sub 3/-HfO/sub 2/ laminate gate dielectric with EOT = 1.95 nm. The McNutt, Maserjian, and Ricco techniques were found to have significant problems. The extraction plots were nonlinear in the case of both the McNutt and the Maserjian techniques; different linear fits could be made to different parts of the accumulation region, leading to multiple and/or improbable values for the gate dielectric capacitance. The Ricco factor had multiple zeros, leading to the same consequence. In addition to C/sub di/, and an experimental quantization index /spl beta/, the proposed technique also yields an experimental /spl phi//sub s/ versus bias for the accumulation regime.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.