Abstract

The electrical parameters (8 × 8 LRGC matrices) of 8-coupled uniform lossy transmission lines were extracted from 40 S-parameter values measured by using 2-port VNA measurements, where all the ports other than 2 VNA ports were terminated by 50 ohm chip resistors. It was assumed in the extraction step that the transmission lines are weakly-coupled, and that the resistance values of all the termination chip resistors are exactly 50 ohms with the second reflections neglected. Comparison of the extracted LRGC matrix components with those from a commercial 3D field solver revealed on average and a maximum relative difference of 2.45% and 7.66%, respectively. In addition, the time-domain crosstalk voltage waveforms in the measured data and those in the SPICE simulation results using the extracted LRGC parameters agreed very well with the average difference and the maximum relative difference in peak crosstalk voltages of 4.15% and 9.68%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.