Abstract

The problem of extraction of a substance in a column is considered for the case of solid spherical particles with the polydisperse composition when mass transfer is controlled by the liquid phase resistance and the distribution coefficient of the extractable substance is constant. For the exponential size-particle distribution we present the results of the corresponding calculation of the extraction degree. It is shown that for the normal distribution the calculation of the extraction degree can be performed without reference to polydispersity of the particles with an accuracy sufficient for engineering computations. The calculations were carried out in the range of values for the volume fraction of the particles from 0 to 0.666.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.