Abstract

Abstract Chromatographic resin containing extractants such as octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) or bis-(2-ethylhexyl)phosphoric acid (HDEHP) or mixture of extractants (CMPO + HDEHP) in an acrylic polymer matrix was prepared and studied for the extraction of Am(III) and Eu(III) over a range of nitric acid concentration. The effect of various parameters such as concentration of nitric acid in aqueous phase and the concentration of CMPO and HDEHP in the resin phase was studied. The distribution coefficient of Am(III) and Eu(III) in the impregnated resin increased with increased in the concentration of nitric acid for CMPO-impregnated resin, whereas a reverse trend was observed in HDEHP impregnated resin. In case of resin containing both the extractants, synergism was observed at low nitric acid concentration and antagonism at high nitric acid concentration. The mechanism of extraction was probed by slope analysis method at 0.01 and 2 M nitric acid concentrations. Citrate-buffered DTPA was used for the selective separation of Am(III), and a separation factor of 3–4 was obtained at pH 3.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.