Abstract

ABSTRACTRotational components of earthquake ground motion have not been considered for seismic analysis, design and performance assessment because recordings of these components are unavailable. A number of procedures have been proposed to extract rotational components of ground motion from translational time series recorded at multiple, closely spaced recording stations. In this paper, a new procedure that is capable of capturing higher frequency content in rotational time‐series is presented. The frequencies at which numerical errors are introduced in the solution, which are a function of apparent wave velocity and array dimension, are identified. Results are presented for the proposed procedure, the widely accepted geodetic method, and a single‐station procedure developed by the authors, all using data recorded at the Lotung array in Taiwan. Copyright © 2012 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.