Abstract
This paper presents a method for extracting the coupling matrix and the unloaded Q from the measured (or electromagnetic simulated) S-parameters of a narrow band cross-coupled resonator bandpass filter with losses. The Cauchy method is applied to determine the characteristic polynomials of the S-parameters of a filter in the normalized low-pass frequency domain. A five-parameter optimization method is proposed to obtain the unloaded Q and to remove the phase shift of the measured S-parameters, which is caused by the phase loading and the transmission lines at the input/output ports of a filter. Once the characteristic polynomials of the S-parameters with the phase shift removed have been determined, the coupling matrix of a filter with a given topology can be extracted using well established techniques. Two application examples are given to illustrate the validity of the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.