Abstract
Presence of an extra-articular deformity in the femur or tibia poses a challenge to the surgeon undertaking knee replacement procedure. The conundrum is whether to correct the deformity beforehand, or accept the deformity and compensate for this through placement of the implant. This is a retro-spective study comprising six patients who had a knee replacement in the presence of an extra-articular deformity of the tibia treated at our centre. All six had the knee replacement without correction of deformity. The data evaluated included clinical outcome, mechanical axis correction, type of implant, and the use of any software / computer guidance. Mean age was 66.5 years. Mean coronal plane deformity in the tibia was 8.6 degrees. The hip- knee-ankle improved from a mean 12.6 degrees to 4 degrees. Mean Oxford knee score improved from a mean of 19 to 33.6. Planning the tibial resection on the basis of mechanical axis of tibia allows correction of alignment without the need for preoperative correction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.