Abstract

Abstract : Computations are performed to examine the effectiveness of mono-disperse water droplets in extinguishing a co-flow, propane diffusion flame by injecting the droplets into the air stream. The calculations show that the droplets entrained into the reaction kernel at the flame base are crucial for extinction. The reaction kernel detaches from the burner rim and blows-off when the droplet concentration is increased to a critical value (extinction concentration). At the critical value, the maximum chain-branching reaction (H2+O=OH+H) rate in the reaction kernel was found to be reduced by a factor of 5 in our computations. A large decrease in the reaction rate indicates that the maximum heat generations rate and Damkholer number are too low to sustain the flame, and cause the flame blow-off. Large drops are more effective than small drops, and the extinction concentration of water increases from 10.5% to 15% by mass as the size is reduced from 32 to 4 micro m. As the droplet size is increased further (>32 micro m), the trend will reverse as the evaporation rates get too small despite increased penetration of flame core by the drops.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.