Abstract
Abstract Background The European Society of Cardiology (ESC) high sensitivity cardiac troponin T 0/1h-algorithm has substantially improved the management of patients with suspected acute myocardial infarction (AMI) by triaging about 75% of patients to rapid rule-out and/or rapid rule-in. However, about 25% of patients remain in the “observe-zone”, and the optimal management of these patients is unknown. Recently, a pilot single center study with a low prevalence of AMI suggested that an absolute change of less than 7ng/L between the 0h and 3h hs-cTnT concentration would allow to help in the evaluation of patients in the observe-zone and allow triage towards rule-out with very high negative predictive value [NPV]. Purpose To externally validate this suggested modification of the ESC 0/1h-algorithm for early rule out of AMI. Methods In an ongoing multicentre international study, we prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of MI. Final diagnoses were centrally adjudicated by two independent cardiologists using all available medical records obtained during clinical care including 90 day follow-up information and cardiac imaging. High sensitivity-cTnT (Elecsys) concentrations were measured at presentation and after 1 and 3 hours. The primary outcome was safety, quantified by the sensitivity and NPV for early rule out of NSTEMI. Results Among 1633 enrolled patients with available 0, 1 and 3h hs-cTnT concentrations, NSTEMI was the adjudicated final diagnosis in 337 (20.6%) patients. The ESC 0/1h-algorithm ruled out 918 (56.2%) patients, with a sensitivity of 98.8% (95% confidence interval [CI], 97.0–99.5) and a NPV of 99.6% (95% CI, 98.9–99.8). A total of 428 patients (26.2%) remained in the observe zone. After applying the suggested 0–3 hour absolute change cut-off criteria of 7ng/L, 393 (92.0%) additional patients from the observe zone were triaged towards ruled out. However, the safety of this triage step was poor with 62 patients with NSTEMI missed, resulting in a sensitivity of 33.3% and a NPV of 84.2% for rule-out. Conclusions The suggested 0/3h absolute change cut-off of 7ng/L for patients remaining in the observe zone of the ESC 0/1h-algorithm does NOT allow safe rule-out of AMI and should therefore NOT be implemented into routine clinical care. Figure 1 Funding Acknowledgement Type of funding source: Public grant(s) – National budget only. Main funding source(s): Swiss National Science Foundation, the Swiss Heart Foundation, the Stiftung für kardiovaskuläre Forschung Basel, the University of Basel and the University Hospital Basel
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.