Abstract

We performed a prospective, randomised study to compare the Ex-fi-re external fixator (EF) with locked intramedullary (IM) nailing in tibial fractures. Only fractures without soft-tissue problems of importance were included. Ex-fi-re is a unilateral, dynamic axial fixator with fracture reduction capabilities. The Grosse-Kempf nail was used for nailing. A total of 78 patients with 79 fractures were entered in the study (41 Ex-fi-re, 38 IM nails). Time to radiographic union and full weight-bearing did not differ significantly, but unprotected weight-bearing was achieved earlier in the IM group (12 vs 20 weeks; p<0.001). There were more reoperations due to secondary dislocation in the EF group. There were no differences in final angulation or shortening. After 6 months and 1 year there were no differences in knee motion, ankle motion, fracture site pain or ankle pain. Some 64% of the nailed patients complained of anterior knee pain after 1 year. The results were comparable in most respects. Unprotected weight-bearing was achieved earlier after IM nailing. Anterior knee pain was frequent after nailing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.