Abstract

The accuracy of measurement of opening mode stress intensity factor using strain gage techniques mainly depends on location of the strain gages. The present work proposes a finite element based simple procedure for accurate determination of three parameter zone and optimum strain gage location for various eccentric cracked configurations. In this paper, the effect of specimen size and crack length to width of the eccentric cracked plate on optimum location of strain gage is also studied. The results of the present investigation show that specimen size and ratio of crack length to width of the plate strongly influence the optimum location of strain gage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.