Abstract

EC3 provides several methodologies for the stability verification of members and frames. Regarding tapered beam-columns, in EC3-1-1, the safety verification may be performed by the General Method. However, application of this method has been shown not to be reliable. On the other hand, the interaction formulae in EC3-1-1 were specifically calibrated for stability verification of prismatic members.Recently, Ayrton–Perry based proposals for the stability verification of web-tapered columns and beams, in line with the Eurocode principles for the stability verification of prismatic members, have shown to lead to a substantial increase of accuracy and to provide mechanical consistency relatively to application of the General Method. Such methodologies may be further applied to the existing interaction formulae.It is the purpose of this paper to propose a verification procedure for the stability verification of web-tapered beam-columns under in-plane loading by adaptation of the interaction formulae in EC3-1-1, validated through extensive FEM numerical simulations covering several combinations of bending moment about strong axis, My, and axial force, N, and levels of taper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.