Abstract

The authors have previously demonstrated how a transmitter (Tx), a reciprocal transmitter/receiver (Tx/Rx) signal path and two unidirectional receiver (Rx) paths can be used together with short, open and load standards for the absolute vector error correction (AVEC) of a Tx/Rx module. Once calibrated, this Tx/Rx module can then provide accurate vector measurements of the signals that are flowing into and/or out of the test port. In order to simplify the analysis, the AVEC technique was applied to a simplified baseband circuit that did not include frequency conversion mixers in a previous paper. Now, in this paper the authors first show how the AVEC technique can be extended to the vector calibration of high-frequency receivers that involve frequency conversion mixers. The authors then show how to calibrate a system that allows for wideband absolute phase relationship measurements of periodic modulated signals, provided that the same local oscillator is employed for the two down-conversion receivers, and different radio frequencies and intermediate frequencies are employed in these receivers. This novel AVEC technique is one of the key concepts in the design of a wideband absolute vector signal measurement system, which overcomes the limitations of traditional measurement instruments by combining the features of vector signal analysers, spectrum analysers and vector network analysers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call