Abstract

BackgroundVariations in plasma properties among spectra and samples lead to significant signal uncertainty and matrix effects in laser-induced breakdown spectroscopy (LIBS). To address this issue, direct compensation for plasma property variations is considered highly desirable. However, reliably compensating for the total number density variation is challenging due to inaccurate spectroscopic parameters. For reliable compensation, a total number density compensation (TNDC) method was presented in our recent work, but its applicability is limited to simple samples because of its strict assumptions. In this study, we propose a new pre-processing method, namely extended TNDC (ETNDC), to reduce signal uncertainty and matrix effects in the more complex analytical task of uranium determination. ResultsETNDC reflects the total number density variation with a weighted combination of spectral lines from all major elements and incorporates temperature and electron density compensation into the weighting coefficients. The method is evaluated on yellow cake samples and combined with regression models for uranium determination. Using the typical validation set and line combination, the mean relative standard deviation (RSD) of U II 417.159 nm in validation samples decreases from 4.92% to 2.27%, and the root mean square error of prediction (RMSEP) and the mean RSD of prediction results decrease from 4.81% to 1.93% and from 1.92% to 1.56%, respectively. Furthermore, the results of 10 validation sets and 216 line combinations show that ETNDC outperforms baseline methods in terms of average performance and robustness. SignificanceFor the first time, ETNDC explicitly addresses the temperature and electron density variations while compensating for the total number density variation, where the inaccurate spectroscopic parameters are avoided by fitting related quantities using concentration information. The method demonstrates effective and robust improvement in signal repeatability and analytical performance in uranium determination, facilitating accurate quantification of the LIBS technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.