A model based on-line foul monitoring approach for a power plant reheater is proposed. Dual Extended Kalman Filter (DEKF) is designed to estimate the model parameters that influence fouling. Based on the estimated parameters the performance index (Cleanliness Factor) is obtained to retrieve the extent of fouling on reheater. The simulation and experimental validation using power plant data shows the efficacy of DEKF over conventional Joint-EKF (JEKF) in estimating the model parameters. The outcome of the work will assist in soot blow scheduling for reheater by perceiving the fall in cleanliness factor and will also help in analysing its impact on heat transfer efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.