Abstract

PurposeThe reuse of reprocessed single-use suction catheter for suctioning an amount of tracheal secretion among orally intubated, mechanically ventilated patients, who are at risk of acquiring ventilator-associated pneumonia (VAP), has not been thoroughly investigated. This study aimed to examine the association between the repetitive use of reprocessed single-use suction catheter and VAP development. Materials and methodsA preliminary, single unit–based investigation was designed as matched case-control study to extract data from hospital's existing 5-year VAP report and inpatients' clinical records. Cases were defined as patients, who developed VAP between December 2009 and October 2014. Controls were defined as patients, who had no evidence of VAP during study period. Six hundred eight controls were frequency matched to 152 cases in 4:1 ratio. Chart-extracted clinical data were stratified and included for conditional logistic regression analysis. ResultsAnalysis showed a significant association between reprocessed single-use tracheal suction catheter exposure and VAP development [odds ratio (OR), 3.64; 95% confidence interval (CI), 2.47-5.35]. A statistically significant increase in VAP risk was found in male intubated patients (OR, 5.33; 95% CI, 1.22-23.3), who are older than 60 years (OR, 8.08; 95% CI, 1.47-44.3), had severe Glasgow Coma Scale scores (OR, 8.27; 95% CI, 1.83-37.3), and received mechanical ventilatory support for more than 96 hours (OR, 9.67; 95% CI, 1.98-47.1). In addition, a statistically significant increase in VAP risk was seen in intensive care unit, where reprocessed tracheal suction catheter changes were routinely provided (OR, 16.0; 95% CI, 2.40-106.7) and unsatisfactory hand hygiene percentage compliance was observed (OR, 8.40; 95% CI, 1.60-44.1). Ventilator-associated pneumonia proportion analysis revealed a higher number of unknown exogenous VAP among exposed cases compared to nonexposed case patients (32.2% vs 13.8%; OR, 2.31; 95% CI, 1.31-4.05; P < .005) that were mechanically ventilated for more than 96 hours (62.5% vs 25.7%; OR, 3.62; 95% CI, 2.40-5.46; P < .0001). ConclusionsThis current study suggests that exposure to reprocessed single-use tracheal suction catheter may predispose orally intubated, mechanically ventilated patients in developing VAP. Further research studies are recommended to validate these findings. Implications for clinical nursing practiceThe estimated VAP risk of this traditional-based practice is essential to provide strong basis for infection control measures to reduce, if not totally eliminate, VAP.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.