Abstract

The association between childhood leukemia and extremely low frequency magnetic fields (ELF-MF) generated by power lines and various electric appliances has been studied extensively during the past 40years. However, the conditions under which ELF-MF represent a risk factor for leukemia are still unclear. Therefore, we have performed a systematic review and meta-analysis to clarify the relation between ELF-MF from several sources and childhood leukemia. We have systematically searched Medline, Scopus, Cochrane Database of Systematic Review and DARE to identify each article that has examined the relationship between ELF-MF and childhood leukemia. We have performed a global meta-analysis that takes into account the different measures used to assess magnetic field exposure: magnetic flux density measurements (<0.2µT vs. >0.2µT), distances between the child's home and power lines (>200m vs. <200m) and wire codings (low current configuration vs. high current configuration). Moreover, meta-analyses either based on magnetic flux densities, on proximity to power lines or on wire codings have been performed. The association between electric appliances and childhood leukemia has also been examined. Of the 863 references identified, 38 studies have been included in our systematic review. Our global meta-analysis indicated an association between childhood leukemia and ELF-MF (21 studies, pooled OR=1.26; 95% CI 1.06-1.49), an association mainly explained by the studies conducted before 2000 (earlier studies: pooled OR=1.51; 95% CI 1.26-1.80 vs. later studies: pooled OR=1.04; 95% CI 0.84-1.29). Our meta-analyses based only on magnetic field measurements indicated that the magnetic flux density threshold associated with childhood leukemia is higher than 0.4µT (12 studies, >0.4µT: pooled OR=1.37; 95% CI 1.05-1.80; acute lymphoblastic leukemia alone: seven studies, >0.4µT: pooled OR=1.88; 95% CI 1.31-2.70). Lower magnetic fields were not associated with leukemia (12 studies, 0.1-0.2µT: pooled OR=1.04; 95% CI 0.88-1.24; 0.2-0.4µT: pooled OR=1.07; 95% CI 0.87-1.30). Our meta-analyses based only on distances (five studies) showed that the pooled ORs for living within 50m and 200m of power lines were 1.11 (95% CI 0.81-1.52) and 0.98 (95% CI 0.85-1.12), respectively. The pooled OR for living within 50m of power lines and acute lymphoblastic leukemia analyzed separately was 1.44 (95% CI 0.72-2.88). Our meta-analyses based only on wire codings (five studies) indicated that the pooled OR for the very high current configuration (VHCC) was 1.23 (95% CI 0.72-2.10). Finally, the risk of childhood leukemia was increased after exposure to electric blankets (four studies, pooled OR=2.75; 95% CI 1.71-4.42) and, to a lesser extent, electric clocks (four studies, pooled OR=1.27; 95% CI 1.01-1.60). Our results suggest that ELF-MF higher than 0.4µT can increase the risk of developing leukemia in children, probably acute lymphoblastic leukemia. Prolonged exposure to electric appliances that generate magnetic fields higher than 0.4µT like electric blankets is associated with a greater risk of childhood leukemia.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call