Abstract

For two different in vivo exposure setups body-mounted antenna systems have been designed. The first setup is designed for investigation of volunteers during simulated mobile phone usage. The setup consists of a dual-band antenna for GSM/WCDMA with enhanced carrying properties, which enables exposure for at least 8 h a day. The 10 g averaged localised SAR--normalised to an antenna input power of 1 W--measured in the flat phantom area of the SAM phantom amounts to 7.82 mW g(-1) (900 MHz) and 10.98 mW g(-1) (1966 MHz). The second exposure setup is used for a laboratory behavioural study on rats. The design goal was a localised, well-defined SAR distribution inside the animals' heads at 900 MHz. To fulfil the biological requirements, a loop antenna was developed. For tissues around the ears, a localised SAR value of 50.12 W kg(-1) averaged over a mass of 2.2 g for an antenna input power of 1 W is obtained.