Abstract

Abstract This paper is a report of an experimental programme on the explosion protection of bucket elevators by venting. The project was a collaborative effort with funding by the Health and Safety Executive and manufacturers and users of bucket elevators through the British Materials Handling Board. Two bucket elevators were used in the project—a single leg elevator and a twin-leg elevator. Four dusts were used with KSt values up to 211 bar m s−1 and dust clouds were produced by dust injection and by normal operation. Reduced explosion pressures were measured and guidance has been derived from the results. This guidance is in terms of vent spacing as a function of the KSt value of the dust.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.