Abstract

Water spray is an economical and environment-friendly alternative to mitigate gas explosion. This study conducts explosion risk analysis (ERA)-based water spray mitigation analysis of ultra-deep-water semi-submersible platform. 5000 gas explosion simulations with and without water spray are conducted by using FLACS codes. The outcome demonstrates that water spray with droplet size 700 μm and water application rate (WAR) 26 L/m2 min is most effective to mitigate explosion scenarios. The droplet size is the significant factor to stimulate the mitigation effect of water spray under middle and small exceedance frequencies, e.g., 1E-05 and 1E-06. WAR becomes dominate to awaken the water spray's negative effect under large exceedance frequency, e.g., 1E-04. A precise and efficient approach of BRANN integrated with artificial bee colony optimization algorithm is used to determine the optimal water spray configuration given the desirable exceedance frequency and the expected design accidental load that the ultra-deep-water semi-submersible platform structures could resist.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.