Abstract

BackgroundIn an increasingly comorbid population, there are significant challenges to diagnosing the cause of breathlessness, and once diagnosed, considerable difficulty in detecting deterioration early enough to provide effective intervention. The burden of the breathless patient on the health care economy is substantial, with asthma, chronic heart failure, and pneumonia affecting over 6 million people in the United Kingdom alone. Furthermore, these patients often have more than one contributory factor to their breathlessness symptoms, with conditions such as dysfunctional breathing pattern disorders—an under-recognized component. Current methods of diagnosing and monitoring breathless conditions can be extensive and difficult to perform. As a consequence, home monitoring is poorly complied with. In contrast, capnography (the measurement of tidal breath carbon dioxide) is performed during normal breathing. There is a need for a simple, easy-to-use, personal device that can aid in the diagnosis and monitoring of respiratory and cardiac causes of breathlessness.ObjectiveThe aim of this study was to explore the use of a new, handheld capnometer (called the N-Tidal C) in different conditions that cause breathlessness. We will study whether the tidal breath carbon dioxide (TBCO2) waveform, as measured by the N-Tidal C, has different characteristics in a range of respiratory and cardiac conditions.MethodsWe will perform a longitudinal, observational study of the TBCO2 waveform (capnogram) as measured by the N-Tidal C capnometer. Participants with a confirmed diagnosis of asthma, breathing pattern disorders, chronic heart failure, motor neurone disease, pneumonia, as well as volunteers with no history of lung disease will be asked to provide twice daily, 75-second TBCO2 collection via the N-Tidal C device for 6 months duration. The collated capnograms will be correlated with the underlying diagnosis and disease state (stable or exacerbation) to determine if there are different TBCO2 characteristics that can distinguish different respiratory and cardiac causes of breathlessness.ResultsThis study’s recruitment is ongoing. It is anticipated that the results will be available in late 2018.ConclusionsThe General Breathing Record Study will provide an evaluation of the use of capnography as a diagnostic and home-monitoring tool for various diseases.Registered Report IdentifierRR1-10.2196/9767

Highlights

  • Burden of BreathlessnessRespiratory and cardiac diseases that cause breathlessness are both highly prevalent and major causes of health care utilization across the United Kingdom

  • It is anticipated that the results will be available in late 2018

  • The General Breathing Record Study will provide an evaluation of the use of capnography as a diagnostic and home-monitoring tool for various diseases

Read more

Summary

Objective

The aim of this study was to explore the use of a new, handheld capnometer (called the N-Tidal C) in different conditions that cause breathlessness. We will study whether the tidal breath carbon dioxide (TBCO2) waveform, as measured by the N-Tidal C, has different characteristics in a range of respiratory and cardiac conditions

Methods
Conclusions
Introduction
Aims and Objectives
Study Participants
Moderate to severe asthma defined as British Thoracic Society stage 3 to 5
Study Procedures
Schedule
Summary Statistics
Discussion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call