Abstract

Motion artefacts (MAs) are induced within EEG data collected simultaneously with fMRI when the subject's head rotates relative to the magnetic field. The effects of these artefacts have generally been ameliorated by removing periods of data during which large artefact voltages appear in the EEG traces. However, even when combined with other standard post-processing methods, this strategy does not remove smaller MAs which can dominate the neuronal signals of interest. A number of methods are therefore being developed to characterise the MA by measuring reference signals and then using these in artefact correction. These methods generally assume that the head and EEG cap, plus any attached sensors, form a rigid body which can be characterised by a standard set of six motion parameters. Here we investigate the motion of the head/EEG cap system to provide a better understanding of MAs. We focus on the reference layer artefact subtraction (RLAS) approach, as this allows measurement of a separate reference signal for each electrode that is being used to measure brain activity.Through a series of experiments on phantoms and subjects, we find that movement of the EEG cap relative to the phantom and skin on the forehead is relatively small and that this non-rigid body movement does not appear to cause considerable discrepancy in artefacts between the scalp and reference signals. However, differences in the amplitude of these signals is observed which may be due to differences in geometry of the system from which the reference signals are measured compared with the brain signals. In addition, we find that there is non-rigid body movement of the skull and skin which produces an additional MA component for a head shake, which is not present for a head nod. This results in a large discrepancy in the amplitude and temporal profile of the MA measured on the scalp and reference layer, reducing the efficacy of MA correction based on the reference signals.Together our data suggest that the efficacy of the correction of MA using any reference-based system is likely to differ for different types of head movement with head shake being the hardest to correct. This provides new information to inform the development of hardware and post-processing methods for removing MAs from EEG data acquired simultaneously with fMRI data.

Highlights

  • Simultaneous EEG-fMRI is a valuable multi-modal technique for investigating brain function

  • For our experiments, we chose to consider any changes in relative position between markers greater than 0.017 mm to be indicative of non-rigid body movement

  • We used an Moire-phase tracking (MPT) system to assess the movements of the skull, scalp and EEG cap which underlie the Motion artefacts (MAs) that affect EEG data measured during simultaneous fMRI

Read more

Summary

Introduction

Simultaneous EEG-fMRI is a valuable multi-modal technique for investigating brain function. The quality of EEG recordings acquired during an fMRI experiment can be compromised by large artefacts due to interaction of the EEG system (EEG cap, cables and amplifier) and head with the magnetic fields used in MRI. These artefacts are grouped into three distinct types: the gradient artefact (GA) (Yan et al, 2009), the pulse artefact (Debener et al, 2008; Ives et al, 1993; LeVan et al, 2013; Mullinger et al, 2013b; Muri et al, 1998; Yan et al, 2010) and the motion artefact (Fellner et al, 2016; Jansen et al, 2012). The MA is extremely problematic and is the focus of this work

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call