Abstract

A model consisting of a rigid wing with an integral, flexible beam support that was cantilever mounted from the wall in the NASA LaRC 0.3-m transonic cryogenic tunnel was used in a flutter analysis study. The wing had a rectangular planform of aspect ratio 1.5 and a 64A010 airfoil. Various considerations and procedures for conducting flutter tests in a cryogenic wind tunnel were evaluated. Flutter onset conditions were established from extrapolated subcritical response measurements. A flutter boundary was determined at cryogenic temperatures over a Mach number M range from 0.5 to 0.9. Flutter was obtained at two different Reynolds numbers R at M = 0.5 (R = 4.4 and 18.4 x 10 to the 6th power) and at M = 0.8 (R = 5.0 and 10.4 x 10 to the 6th power). Flutter analyses using subsonic lifting surface (kernel function) aerodynamics were made over the range of test conditions. To evaluate the Reynolds number effects at M = 0.5 and 0.8, the experimental results were adjusted using analytical trends to account for differences in the model test temperatures and mass ratios. The adjusted experimental results indicate that increasing Reynolds number from 5.0 to 20.0 x 10 to the 6th power decreased the dynamic pressure by 4.0 to 6.5 percent at M = 0.5 and 0.8.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call