Abstract

ObjectiveTo evaluate the effect of strategies to reduce the spread of simulated aerosol during chest compressions on manikin and cadaver experimental models. MethodsTo evaluate aerosol-spread we nebulized ultraviolet sensitive detergents into the artificial airway of a resuscitation dummy and performed CPR. The spread of the visualized aerosol was documented by a camera. In a further approach we applied nebulized detergents into the airways of human cadavers and detected the simulated spread on the same way. Among others we did recordings with undergoing compression-only-CPR, with a surgical mask or an oxygen mask on the patients face and with an inserted supraglottic airway device with and without a connected airway filter. ResultsMost aerosol-spread at the direction of the provider was visualized during compression-only-CPR. The use of a surgical mask and of an oxygen mask on the patient's face deflected the spread. Inserting a supraglottic airway device connected to an airway filter lead to a remarkable reduction of aerosol-spread. ConclusionThe early insertion of a supraglottic airway device connected to an airway filter before starting chest compression may be beneficial for staff protection during CPR.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.