Abstract

The α-class carbonic anhydrase (CA) from the thermophilic gammaproteobacterium Thiomicrospira crunogena XCL-2 (TcruCA) has been recently proposed as a candidate enzyme for carbon dioxide removal (CDR) in flue gas scrubbing systems. However during this process, the enzyme may be exposed to anionic impurities which can limit the use of CA for CDR. The inhibition of TcruCA by various anions, some of which are found in flue gas, is reported. The majority of the anions tested display weak (mM) inhibition but some, such as the metal poisons and anionic acids, exhibit stronger (μM) inhibition. Most relevant to the use of CA in CDR is the inhibition by SOx, NOx, and Hg2+, which can be removed through a pre-scrubbing treatment. In addition, the active site structural architecture of TcruCA is compared with other α-class CAs and differences in catalytic efficiency and anion inhibition are discussed. This study provides information regarding anionic inhibition of CAs as bio-catalytic CDR agents and the results should therefore be considered in the design of CA-mediated flue gas scrubbing systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.