Abstract

Magnetization AC loss measurements have been performed by the calibration free method on mono, 19 filaments un-twisted and 19 filaments twisted MgB2 superconducting wires with magnetic fields perpendicular to the wire axis at various frequencies and temperatures between 24 and 40 K. AC losses were also calculated based on critical state model for mono-filamentary Nb sheathed MgB2 wire with conditions corresponding to experiments. Good agreement is observed between model and experimental data. AC losses go through a peak when the wire was cooled below Tc. In terms of AC magnetization losses, the twisted wire has the minimum losses in order of 10−5 J/m at 30 K in AC magnetic field with 20 mT amplitude.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.