Abstract

This paper deals with experimental works and analysis for influence of stator slot number on performance of interior PM (IPM) motor. First, for a conventional 6-pole IPM rotor, stators with 18, 27 and 36 slots satisfied with same required and restricted conditions are designed. And then, performances and parameters of each IPM motor such as cogging torque, torque ripple, d- and q- axis inductance, total harmonic distortion (THD) of back-emf, etc. are investigated using 2-d finite element analyses (FEA). Finally, test results such as d- and q- axis inductance, back-emf and efficiency measurements are given to confirm analysis results. It is concluded from the results obtained by this work that the influence of stator slot number on IPM motor behavior is very significant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.