Abstract

This study aims to evaluate the effect of various parameters on the behavior of the reinforced concrete flat slabs and the contribution of each design element in the punching shear strength. This research presents experimental results of tested post-tensioned flat slabs with opening under concentric compressive load. The developed post-tensioned flat slabs are to ensure adequate punching shear strength capacity. The experimental work consisted of eight specimens of post-tensioned reinforced concrete flat slabs which classified into groups. All slabs had the same dimension and reinforcement. The slabs had dimensions with a 1750 mm length and 1750 mm width, to study the behavior of post-tensioned flat slab with/out openings under the concentrated load and punching influence.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.