Abstract
This paper presents a dynamic model of the active front-end (AFE) converter under the synchronous reference frame. Transfer functions of the closed-loop control based on this dynamic model are verified experimentally in the frequency domain. Bode plots of these transfer functions are given to validate this synchronous frame-based dynamic model. Based on these results, this paper presents the control designs of the AFE converter to enhance the disturbance rejection capability and robustness. The control designs are then verified experimentally in the frequency domain. The frequency response of the AFE converter system is measured by an agilent 35670A dynamic signal analyzer to validate the performance of the AFE converter system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.