Abstract
Findings are presented from the tests of balanced control valve mounted on the steam piping with experimental turbine. The forces applied on the spindle are recorded and compared to design calculation. The forces are evaluated from the pressures on a servo drive piston or they are measured directly using force transducers. The real operational characteristics are compared with characteristics defined for constant inlet pressure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.