Abstract
AbstractThis paper reports on the experimental validation characteristics of a salient pole synchronous motor with the starting field circuit in contact. The starting characteristics were experimentally evaluated at voltages of 100%, 75%, and 50% using a 1.5 kVA salient pole synchronous motor. The signal for pulling into step was applied to the field circuit by using the control module for all test conditions. The results confirmed the proper pulling into step at 100% of voltage, and the results of the tests at 50% and 75% of voltage revealed that the pulling into step under these conditions becomes stable at the suitable slip condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.